The set includes:
Sirius Unified (boost pressure / water temperature), control unit, OBD harness, dedicated meter stay / meter branch harness
Product Features
ISO CAN communication vehicle of fault diagnosis connector ( It is OBD II) one-touch can be connected to the meter. Self-luminous type transmission type "Sirius vision" as a guideline type of "Sirius meter" next-generation additional meter which is a combination of. - 12V vehicles only
- ISO CAN communication corresponding
* sensor is not included.
specification
- The analog section includes boost gauge, water temperature gauge, oil temperature gauge, oil pressure gauge, and fuel pressure gauge.
- A sensor harness is included with each lineup.
- The meter's pointer movement and the vision's digital display are displayed in tandem. It is also possible to display information on the vision that is different from the meter. (A sensor and harness that correspond to the display items of the sirius vision are required separately.)
- "Sirius control unit" is required separately.
Pre-purchase information:
If you have a GReddy SIRIUS series (Unified/Vision/Control Unit) with a serial number earlier than GSI-8000 , you may need to update it when using it together with a GReddy SIRIUS series after GSI-8000 . For details, please visit the following website.
Warranty Information
- The warranty period is one year from the date of purchase, which is stated on the warranty card.
- This is only valid if the malfunction occurs under normal usage conditions.
- Please be sure to ask the retailer where you purchased the product to fill in the name of the retailer and the date of purchase.
- The warranty will be void if the store name or purchase date is not filled in, or if it appears to have been corrected.
- We do not reissue warranty cards, so please keep them in a safe place.
Measurement upper/lower limit of display items, lighting brightness
Pointer meter section
Value Display Range | WARNING default value | remarks | |
---|---|---|---|
Boost Pressure | -0.99 to 2.5 (kPa) | 1.20(kPa) | |
water temperature | 0 to 120 (℃) | 100(℃) | |
oil temperature | 20 to 140 (℃) | 120(℃) | |
Hydraulic | 0 to 10.0 (kPa) | 1.0(kPa) | *Lower limit warning |
Fuel pressure | 0 to 10.0 (kPa) 0 to 6.0 (kPa) | 1.5(kPa) | *Lower limit warning |
Daytime light intensity | Night light amount | |
---|---|---|
Lighting brightness | 7 | 3 |
Digital meter section
Value Display Range | WARNING default value | remarks | |
---|---|---|---|
Boost Pressure | -0.99 to 2.5 (kPa) | 1.20(kPa) | |
water temperature | 0 to 120°C | 100(℃) | |
oil temperature | 20 to 140°C | 120(℃) | |
Hydraulic | 0 to 10.0 (kPa) | 1.0(kPa) | *Lower limit warning |
Fuel pressure | 0 to 6.0 (kPa) | 1.5(kPa) | *Lower limit warning |
General temperature 1/2 | 20 to 140°C | 120(℃) | |
General Purpose Pressure | 0 to 10.0 (kPa) | 1.0(kPa) | *Lower limit warning |
Battery voltage | 9 to 18.0 (V) | 1.0(kPa) 10.0(V) | *Lower limit warning |
Daytime light intensity | Night light amount | |
---|---|---|
Lighting brightness | 7 | 3 |
operating instructions
Please read the precautions carefully before using.
Precautions:
・The copyright of the instruction manual belongs to Trust Co., Ltd. Copying or revising the contents of the instruction manual, in whole or in part, without the permission of the copyright holder is prohibited under copyright law. However, this does not apply to partial copying only for personal use other than commercial transactions.
・In principle, the published instruction manuals are those originally published when the product was released, and the contents of the instruction manual published on this site may differ from the specifications of the product you own due to subsequent changes in specifications. Therefore, please note that the contents of the instruction manual published on this site may differ from the instruction manual included with your model or the instruction manual included with models currently on the market.